ZhcxInsideInspectionDetailImprovementItemDo.java 2.6 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129
  1. package com.rongwei.bsentity.domain;
  2. import com.baomidou.mybatisplus.annotation.TableName;
  3. import com.rongwei.rwcommon.base.BaseDo;
  4. import java.util.Date;
  5. import com.baomidou.mybatisplus.annotation.TableField;
  6. import lombok.Data;
  7. import lombok.EqualsAndHashCode;
  8. import lombok.experimental.Accessors;
  9. /**
  10. * <p>
  11. * 内部报验-报验管理-细节完善项
  12. * </p>
  13. *
  14. * @author wm
  15. * @since 2024-10-22
  16. */
  17. @Data
  18. @EqualsAndHashCode(callSuper = true)
  19. @Accessors(chain = true)
  20. @TableName("ZHCX_INSIDE_INSPECTION_DETAIL_IMPROVEMENT_ITEM")
  21. public class ZhcxInsideInspectionDetailImprovementItemDo extends BaseDo {
  22. private static final long serialVersionUID=1L;
  23. /**
  24. * 主键
  25. */
  26. @TableField("ID")
  27. private String id;
  28. /**
  29. * 租户ID
  30. */
  31. @TableField("TENANTID")
  32. private String tenantid;
  33. /**
  34. * 扩展预留
  35. */
  36. @TableField("ROPTION")
  37. private String roption;
  38. /**
  39. * 内部报验单id
  40. */
  41. @TableField("INSIDEID")
  42. private String insideid;
  43. /**
  44. * 细节完善项id
  45. */
  46. @TableField("ITEMID")
  47. private String itemid;
  48. /**
  49. * 细节完善项编码
  50. */
  51. @TableField("ITEMCODE")
  52. private String itemcode;
  53. /**
  54. * 细节完善项名称
  55. */
  56. @TableField("ITEMNAME")
  57. private String itemname;
  58. /**
  59. * 检查项
  60. */
  61. @TableField("INSPECTON_ITEMS")
  62. private String inspectonItems;
  63. /**
  64. * 接收条件
  65. */
  66. @TableField("RECEIVING_CONDITIONS")
  67. private String receivingConditions;
  68. /**
  69. * 依据标准
  70. */
  71. @TableField("ACCORDING_TO_STANDARDS")
  72. private String accordingToStandards;
  73. /**
  74. * 依据标准图片
  75. */
  76. @TableField("ACCORDING_TO_FILES")
  77. private String accordingToFiles;
  78. /**
  79. * 自检员实测记录
  80. */
  81. @TableField("SELFACTUALRECORD")
  82. private String selfactualrecord;
  83. /**
  84. * 自检员结果判定
  85. */
  86. @TableField("SELFRESULT")
  87. private String selfresult;
  88. /**
  89. * 自检员附件
  90. */
  91. @TableField("SELFFILES")
  92. private String selffiles;
  93. /**
  94. * 自检员备注
  95. */
  96. @TableField("SELFREMARK")
  97. private String selfremark;
  98. /**
  99. * 检验员实测记录
  100. */
  101. @TableField("CHECKACTUALRECORD")
  102. private String checkactualrecord;
  103. /**
  104. * 检验员结果判定
  105. */
  106. @TableField("CHECKRESULT")
  107. private String checkresult;
  108. /**
  109. * 检验员附件
  110. */
  111. @TableField("CHECKFILES")
  112. private String checkfiles;
  113. /**
  114. * 检验员备注
  115. */
  116. @TableField("CHECKREMARK")
  117. private String checkremark;
  118. /**
  119. * 排序
  120. */
  121. @TableField("SORT")
  122. private Integer sort;
  123. }